MENU+86-0371-67989006 Email:[email protected]No.1 Fuel Dispenser Manufacturer and Fuel Dispensing Equipment of China Market

fuel dispenser shear valve

Quick inquiry
I am interested in . This equipment will be used in (country) . My name is , my Email is , my phone number is . Detailed requirements are . Please send me detailed quotation list!

Shear Valves Jones & Frank

Shear Valves Jones & Frank

Shear Valves. Emergency shear valves are installed on fuel supply lines beneath dispensers at grade level to minimize hazards associated with collision or fire at the dispenser. If the dispenser is pulled over or dislodged by collision, the top of the valve breaks free at the integral shear groove, activating poppets that shut off the flow of fuel.

Kent Reid Inventions, Patents and Patent Applications

Kent Reid Inventions, Patents and Patent Applications

The shear valve may contain a flange for connection to internal fuel dispenser piping that either does or does not includes interstitial space orifices to couple the shear valve interstitial space to the fuel dispenser piping interstitial space to monitor the vacuum or pressure level in these interstitial spaces as one contiguous space.

Genuine Fuel Dispenser Parts Gilbarco Veeder Root

Genuine Fuel Dispenser Parts Gilbarco Veeder Root

The Widest Range of Parts with Multi Dispenser Compatibility. Say goodbye to service, maintenance, and upgrade woes with genuine Gilbarco fuel dispenser parts. Choose from a wide range of gas dispenser parts including printers, card readers, displays, keypad switches, PC boards, power supplies, valves, meters, pumps and much more.

Ethanol Equipment Options US Department of Energy

Ethanol Equipment Options US Department of Energy

Shear valves are an important piece of safety equipment that stop the flow of fuel from the underground storage tank to the dispenser. They prevent fuel release in the event of an accident dislodging the dispenser or a fire. UL listed E85 shear valves are available from Franklin Fueling and OPW.

Single Poppet Shear Valve Shipman King

Single Poppet Shear Valve Shipman King

A Valve That Provides Emergency Shut Off Protection . The Emergency Shut Off Valve or “Shear Valve” mounts on the supply line within the pedestal base of a fuel dispenser. The valve is equipped with a shear groove and a 165ºF fusible line hold open device.

A Safety Checklist for Fuel Dispensers at Filling Stations

A Safety Checklist for Fuel Dispensers at Filling Stations

  The fuel dispenser assembly includes pipe fittings, shear valves, fuel filters, leak detection sensors, dispenser lines and cathodic protection systems. It’s important that you periodically check the fuel dispenser assembly at least once a week to ensure that everything is working fine.

Fuel dispenser shear valve assembly Google Patents

Fuel dispenser shear valve assembly Google Patents

A shear valve assembly for a fuel dispenser that ensures that the energy from an impact to the fuel dispenser causes a shear valve placed inline to the fuel supply conduit to engage if there is a possibility that such impact could cause the fuel supply conduit to break thereby causing a leak of fuel to the environment. The shear valve assembly may be constructed as part of the fuel dispenser

Piping and Containment Systems Northwest Pump

Piping and Containment Systems Northwest Pump

Dispenser sumps are installed beneath fuel dispensers to provide access to, and secondary containment of, dispenser plumbing, emergency shear valves and underground piping connections. Easily connect a pipework system to other equipment like submersible turbine pump manifolds, shear valves, or even other types of pipework with secure

OPW 70 0070 1 1/2

OPW 70 0070 1 1/2" Vertical Check Valve w/ Shear Groove

The OPW 70 0070 1 1/2" Vertical Check Valve w/ Shear Groove is installed on suction system fuel lines directly below the inlet to the pump in the dispenser island to maintain prime. OPW Vertical Check Valves are recommended for use on suction lines where the pressure does not exceed 34 feet of head (approximately 15 psi (1 bar). 70 Series valves need 1/2" of mercury to activate the poppet.

OPW 10 plus 1 1/2 Inch Double Poppet Emergency Shear

OPW 10 plus 1 1/2 Inch Double Poppet Emergency Shear

OPW Emergency Shear Valves are installed on fuel supply lines beneath dispensers at grade level to minimize hazards associated with collision or fire at the dispenser. If the dispenser is pulled over or dislodged by collision, the top of the valve breaks free at the integral shear groove, activating poppets that shut off the flow of fuel.

Breakaway Shear Valves FFS PRO University

Breakaway Shear Valves FFS PRO University

  Shear valves are an important part of the safety of any fuel dispensing system, stopping product flow in the event of collision or damage at the dispenser. In case of a collision, they work by a specially designed section of the shear valve body separating cleanly upon impact, causing poppet valves to seal on the

Marina Fueling Ace Tank and Fueling Equipment

Marina Fueling Ace Tank and Fueling Equipment

Dispenser shear valves, which minimize collision and fire hazards, fusible link valves, properly sized tidal loops as well as tank level monitors and line leak detectors assure quality control by preventing costly revenue losses and adverse environmental ramifications.

Valves and Fittings Service Station : ARK Petroleum

Valves and Fittings Service Station : ARK Petroleum

OPW Vertical Check Valves are installed on suction system fuel lines directly below the inlet to the pump in the dispenser island to maintain prime. The 70 Series Valves feature a built in shear groove, which helps minimize piping damage if the dispenser is pulled over or dislodged by collision.

Fuel dispenser shear valve assembly Gilbarco Inc.

Fuel dispenser shear valve assembly Gilbarco Inc.

  A shear valve assembly for a fuel dispenser that ensures that the energy from an impact to the fuel dispenser causes a shear valve placed inline to the fuel supply conduit to engage if there is a possibility that such impact could cause the fuel supply conduit to break thereby causing a leak of fuel to the environment.

YOUR PETROLEUM STORAGE TANK FACILITY INSPECTION

YOUR PETROLEUM STORAGE TANK FACILITY INSPECTION

emergency shut off (or shear) valves (make sure you have one on each fuel line), fuel filters, dispenser liners or secondary containment, leak detection sensors, and cathodic protection anodes. (Your dispenser may not need all these items.) 2. Dispenser Island Keep free from open cans or containers to avoid costly accidents. 3.

Motor Fuel Dispensing Facilities

Motor Fuel Dispensing Facilities

Motor fuel dispensing facilities within the borders of the City of Chicago do not undergo the Office of the State Fire Marshal permit application or field inspection process. These motor fuel dispensing facilities are inspected by the City of Chicago. Are dispenser shear valves required to be inspected? Yes. The OSFM rules require that

OPW Shear Valve :: Valves Commercial Fuel Solutions Ltd

OPW Shear Valve :: Valves Commercial Fuel Solutions Ltd

OPW 10 Series Emergency Shut off Valves are designed for installation on fuel supply lines beneath dispensers to minimize hazards associated with collision or fire at the dispenser. If the dispenser is pulled over or dislodged by collision, the top of the valve breaks off at the integral shear groove and isolates the flow of fuel.

Your Petroleum Storage Tank Facility Inspection Guide

Your Petroleum Storage Tank Facility Inspection Guide

1. Dispenser Assembly . Covers should be lockable and keys should be available for monthly inspection. When looking inside the dispenser, check the pipe ittings, emergency shut off (or shear) valves (make sure you have one on each fuel line), fuel ilters, dispenser liners or secondary containment, leak detection sensors, and cathodic protection

Fig. 434 Dispenser Pedestal

Fig. 434 Dispenser Pedestal

of the shear groove on the shear valve is still level with the top of the pedestal. Retighten all the bolts, and nuts inside the pedestal. NOTE: Use provided washers. 9. Repeat these steps for each shear valve being installed. 10. Install the fuel dispenser per the manufacturer’s instructions and all applicable codes. Lengthwise Adjustment

ANS Distributing Service Station Equipment Gas Station

ANS Distributing Service Station Equipment Gas Station

The shear valve is located on the fuel or vapor line directly under the dispenser. In the event of an accident, the valve will close and prevent any more fuel from entering the dispenser. Shear valves are intended for use with pressurized systems and are available in 1