MENU+86-0371-67989006 Email:[email protected]No.1 Fuel Dispenser Manufacturer and Fuel Dispensing Equipment of China Market

permanent closed gauging system on chemical tanker

Quick inquiry
I am interested in . This equipment will be used in (country) . My name is , my Email is , my phone number is . Detailed requirements are . Please send me detailed quotation list!

NYSDEC PBS REGULATIONS Heating Oil Tanks

NYSDEC PBS REGULATIONS Heating Oil Tanks

the UST system has been permanently closed. • A UST system that is permanently closed must be either removed from the ground or filled with an inert solid material (such as sand or concrete slurry). • The facility must submit a copy of records demonstrating compliance with

Safety and Environmental Protection Archives Page 34 of

Safety and Environmental Protection Archives Page 34 of

  Most of the cargoes may be carried in stainless steel or stainless clad tanks. However, due to the high cost involved all chemical tankers may not have such stainless steel or stainless clad tanks. Chemical cargoes may be loaded in tanks coated with suitable coatings. Tanks coatings commonly used are. Zinc silicate; Epoxy; Polyurethane; Phenolic resins

Oil and Chemical Tanker Familiarization Training

Oil and Chemical Tanker Familiarization Training

Oil and Chemical Tanker Familiarization Training. Previous Page Next Page. 3.1 General. This course applies to officers and ratings who will be assigned specific duties and responsibilities related to cargo and cargo equipment on oil or chemical tankers, taking into account section A

Truck Mounted Dispenser Systems Liquip

Truck Mounted Dispenser Systems Liquip

Truck Mounted Dispenser Systems. Units typically include: Inlet strainer and sightglass, hydraulically driven high flow vane pump, high and low flow switch, positive displacement meter with electronic register, air eliminator and strainer, non return valve, hosereel, hose, swivel and nozzle assembly. Meets Weights & Measures regulations (Aus).

Inert Gas on board Tankers All you need to know!

Inert Gas on board Tankers All you need to know!

This means that chemical tankers constructed (keel laid) on or after 1 January 2016, and carrying flammable cargoes such as those listed in the IBC Code chapters 17 and 18, will be required to have a fixed inert gas system, regardless of cargo tank size and tank washing machine capacities.

IBC Code International code for the construction and

IBC Code International code for the construction and

.3 Closed device which penetrates the tank, but which is part of a closed system and keeps tank contents from being released. Examples are the float type systems, electronic probe, magnetic probe and protected sight glass. Alternatively an indirect device which does not penetrate the tank shell and which is independent of the tank may be used.

STANDARDS FOR VAPOUR EMISSION CONTROL SYSTEMS

STANDARDS FOR VAPOUR EMISSION CONTROL SYSTEMS

2.2.1 Each chemical, product or crude carrier should have vapour collection piping which is permanently installed with a tanker vapour connection located as close as practical to the loading manifold. In lieu of permanent piping, Administrations may permit chemical tankers to have a permanent vapour connection at each cargo tank for

MMC Vapor Control Valves, Cam Lock Flanges and Product

MMC Vapor Control Valves, Cam Lock Flanges and Product

Portable Electronic Gauging Tapes for Petroleum and Chemical Tanks CLOSED (GAS TIGHT) and RESTRICTED MMC is the world's leading manufacturer of portable instruments for measuring ullage, oil water interface, temperature, and bottom dryness in shipboard and land based petroleum and chemical tank systems. All MMC

The Case Of The Benzene Bomber Maritime Accident Casebook

The Case Of The Benzene Bomber Maritime Accident Casebook

As the pumpman closes the tank inlet he moves to number six port tank and again takes a reading through the closed ullage port with the MMC gauge. Finally the Chief Officer goes to the cargo control room, contacts the terminal personnel and tells then that

Gauging Wärtsilä

Gauging Wärtsilä

Gauging . 1. Tank gauging, level gauging the process of measuring tank contents. Every modern chemical tanker must have an accurate and reliable tank gauging system. The system must be capable of measuring the tank contents at any level of filling and must be independent of the high level and overflow control system alarms.

Bulk Liquid Chemicals Storage, Transportation and Claims

Bulk Liquid Chemicals Storage, Transportation and Claims

  Bulk Liquid Chemicals Storage, Transportation and Claims is part of IBC Asia Corporate Learning Academy’s Maritime category collection the leaders in training and knowledge.

Tank Gauges Field Instruments FuelsManager Software

Tank Gauges Field Instruments FuelsManager Software

Tank gauging is the generic name given to the measurement of liquids (product) in bulk storage tanks with the aim of quantifying how much product is in the tank, “gauging the contents of a tank”. Today, the oil & gas industry uses the static measurement of the tank contents to account for product stored and product moved into and out of the

A complete guide of cargo Sampling on tankers MySeaTime

A complete guide of cargo Sampling on tankers MySeaTime

  Percentage of cargo loaded at 1 foot = 2 %. As you can see, with only 2 % cargo loaded, it can cover 32% of the cargo tank area. Any contamination because of dirty tank surface should show up in 1 foot of cargo. This avoids the bigger claims if cargo is damaged after loading into the cargo tank.

Product Overview for Marine Applications Honeywell

Product Overview for Marine Applications Honeywell

Manual closed gauging measurements are therefore normally made via a vapour lock valve, using a closed measurement device that provides a gas tight seal when in use. Restricted gauging is the process of taking measurements within a tank using a restricted gauging device

LPG tanker cargo handling equipments & product line system

LPG tanker cargo handling equipments & product line system

CARGO TANK SAMPLE LINES: These are permanently installed sampling pipes which can be used for sampling of liquid cargo or vapour/inert gas/air concentrations when inerting or purging. On some vessels they may also be used in the event of a level gauge failure for tank level gauging.

INTERTANKO TANKER CHARTERING QUESTIONNAIRE 88

INTERTANKO TANKER CHARTERING QUESTIONNAIRE 88

What type of fixed closed tank gauging system is fitted: Floating Number of portable gauging units (example‐ MMC) on board: Hermetic UTI Are overfill (high) alarms fitted? If Yes, indicate whether to all tanks or partial: Yes, all tanks Are cargo tanks fitted with multipoint gauging?

Scot Leipzig IMO 9260847 USCG PSIX

Scot Leipzig IMO 9260847 USCG PSIX

1899 Other (tankers) A chemical tanker shall comply with the requirements of the International Chemical Bulk Code. Cargo tanks shall be fitted with one of the following types of gauging devices: closed devices which penetrates the tanks, but which is part of a closed

PORTABLE TANK MEASURING SYSTEM

PORTABLE TANK MEASURING SYSTEM

Vapor lock installation of portable tank measuring system IMO MARPOL 1973 / 78 ANNEX I, REGULATION 13b (3) SOLAS 1974, REGULATION 60 PARAGRAPH 7 (REQUIREMENT OF CLOSED ULLAGE SYSTEM) IMO MARPOL73 / 78 ANNEX I CHAP II REGULATION 15, (3) (b) SOLAS REGULATION 62, PARAGRAPH 17 Chemical Tankers Crude Oil Tankers Clean Product Tankers

INTERTANKO TANKER CHARTERING QUESTIONNAIRE 88

INTERTANKO TANKER CHARTERING QUESTIONNAIRE 88

What type of fixed closed tank gauging system is fitted: Radar Number of portable gauging units (example‐ MMC) on board: 2 x Hermetic UTI Are overfill (high) alarms fitted? If Yes, indicate whether to all tanks or partial: Yes, All Tanks Are cargo tanks fitted with multipoint gauging?

Measurement and sampling of cargoes on board tank

Measurement and sampling of cargoes on board tank

NOTE Stand pipes are frequently fitted with vapor control valves to allow closed or restricted operation. The pipe should extend to the floor of the tank with the internal part (also called “stilling well” or “still pipe”) slotted to allow free flow of tank contents while providing